Dew Point Sensor WADS 201-204 – Compressed Air Dew Point Meter

Dew Point Sensor

WADS 201/202/203/204


WADS 201-204 Dew Point Sensor - WiseAir India

Dew Point Sensor WADS 201-204


The Wiseair Dew Point Sensor provides reliable and long-term stable dew point monitoring in industrial applications, with a range of -110 … +60 °C Td. It makes it an ideal choice for dew point measurements in high tech requirements and conditions.

The new generation of the dew point sensors offering compressed air users a plug & play solution to monitor their compressed air quality. All transmitter models are available with Analog 4… 20 mA output signals, in addition to that the models are available with a Modbus/RTU digital interface. By offering different output signals users can profit from great flexibility and seamless integration into their process.

Additionally, the dew point sensors are offered with an integrated pressure sensor, combining a pressure and dew point sensor into a single instrument. The main body is made from high class aluminium alloy with a soft finish. Top cover made from aluminium at the same quality as the main body.


Features :

  • For high tech applications with a measurement range of -60°Ctd to +60°Ctd & -80°Ctd to +20°Ctd
  • Quick Response Time
  • Dual Sensor System for high precision over the whole range.
  • Compact size makes them ideal for dryer installations.
  • Accuracy ± 2°C IP65 rated
  • Strong contamination resistance
  • Signal Output: Modbus RTU interface and 4-20mA current / pulse output.
  • Modbus output signal are Pressure Dew Point (PDP), Relative Humidity, Temperature and Optional Integrated pressure transducer
  • 4-20mA output signal are Pressure Dew Point (PDP)
  • CE marked in accordance with applicable EU Directives.
    Declaration of Conformity available upon request.

DEW POINT SENSOR Product Description


WADS 201-204 Dew Point Sensor | Compressed Air Moisture Meter | WiseAir


  • Dew point Sensor – Model Selector Methods
  • SPECIFICATIONS
Dew point Sensor – Model Selector Methods

Model Selector (WADS 200)

Use this selector to generate the correct ordering code based on required measuring range


Select the required dew point measuring range.


For some ranges, Stainless Steel casing will be required.


Auto-selected based on measuring range.


Matched automatically from your selection.


Technology • Casing • Connector

Select Measuring Range (Variant)

Enquire Now


APPLICATIONS

  • Dew point measurement in compressed air systems
  • Dew point measurement during the spray-painting process
  • Dew point measurement in PET bottle production
  • Dew point measurement after refrigerant dryer
  • Dew point measurement / Dryer control of desiccant dryers
  • Dew point monitoring in the pneumatic conveying of powder
  • Dew point monitoring of thermal processing furnaces
  • Dew point measurement for nitrogen or oxygen generators
  • Moisture and oil measurement during wire drawing and cable production
  • Humidity and quality measurement when generating compressed breathing air
SPECIFICATIONS
FeaturesWADS 201WADS 202WADS 203WADS 204
TechnologyCompact DesignPolymerAuto Drift ConectionQuartz
DRYER TYPES – UPTO 40 bar (600psi)
Desiccant DryerAbove -40°CAbove -50°CAbove -60°CBelow -20°C
Membrane DryerAvailableAvailableAvailableAvailable
Refrigerant DryerAvailableAvailable
MEASURING RANGE
Dew Point Range-60°C to +60°C-60°C to +60°C-80°C to +20°C-110°C to +0°C
Operating Pressure Range0 to 40 bar0 to 40 bar (or) 0 to 16 bar0 to 40 bar (or) 0 to 16 bar0 to 40 bar (or) 0 to 16 bar
Gas Temperature Range-40°C to +100°C-40°C to +100°C-40°C to +100°C-40°C to +100°C
AccuracyDew Point : ±2°C
Temperature : ±0.5°C
Dew Point : ±2°C
Temperature : ±0.5°C
Dew Point : ±2°C
Temperature : ±0.5°C
Pressure : ±0.3%
Dew Point : ±2°C
Temperature : ±0.5°C
Pressure : ±0.3%
Minimum Gas Flow Rate>1L / min>1L / min>1L / min>1L / min
OUTPUT SIGNAL
Pressure Dew Point (PDP)AvailableAvailableAvailableAvailable
Gas TemperatureAvailableAvailableAvailableAvailable
Relative HumidityAvailableAvailableAvailableAvailable
Pressure TransducerOptionalOptionalOptional
Analog Output (4…20mA)PDP OnlyPDP OnlyPDP OnlyPDP Only
Digital Output (Modbus/RTU)PDP, Temp, RH, PressurePDP, Temp, RH, PressurePDP, Temp, RH, PressurePDP, Temp, RH, Pressure
OTHERS
Pin Connection5 Pin M85 Pin M125 Pin M125 Pin M12

Installation Video


Watch Now

Application Video


Watch Now

Benefits Of WADS Series

  • Reduces operating and energy costs.
  • Improves downstream filter life and performance.
  • Increase the lifespan of your compressed air system and its components.
  • Reduces maintenance and makes the compressed air system more reliable and efficient.
  • Ensures stable quality of your products through less problems in operation of the system.
  • Enables fast responses to failures in compressed air drying through permanent monitoring of pressure dew point. Reduces risk of bacteria, fungus, and yeast built up.
  • Alerts you to changes in dryer performance before moisture appears in your plant.

Ordering Code


WADS 201-204 Dew Point Sensor | Compressed Air Moisture Meter | WiseAir


Related Products



Related Case Studies & Blogs

Case Study: Why Dew Point Measurement is Important

Learn why monitoring dew point in compressed air systems is critical for product quality, energy savings, and equipment protection.

Read More →

Case Study: Reducing Costs in Your Compressed Air System

Discover how smart monitoring of dew point and flow helped reduce operational costs significantly in industrial compressed air systems.

Read More →

How Compressed Air Monitoring Pays for Itself

A real-world case study showing the ROI of implementing compressed air monitoring with dew point sensors in manufacturing facilities.

Read More →


Frequently Asked Questions

What is dew point in compressed air systems?

Dew point is the temperature at which moisture in compressed air begins to condense into liquid water. Monitoring dew point ensures air quality meets ISO 8573 standards and prevents corrosion and contamination.

Why is dew point monitoring important for compressed air?

Excess moisture in compressed air causes pipe corrosion, product contamination, pneumatic tool damage, and increased energy costs. Dew point sensors help maintain optimal dryer performance.

What dew point range do the WADS 201-204 sensors measure?

The WADS 201-204 series covers a wide dew point measurement range suitable for monitoring refrigerated and desiccant air dryers in industrial compressed air systems.

Product enquiry

Need this for your plant?

Send us your line size, operating pressure and flow range and a WiseAir application engineer will confirm the right model, the delivery time and the price. We manufacture in India, so lead times are weeks rather than months.